GD1303001
Projection Perimeter
Model No.: APS-T00
Features:
1.International standards
•Color perimetry: a more sensitive detection of early visual filed defects
2.Accurate, fast Visual Testing
•Original interlligent testing strategies(IDT):3 minutes to complete a full inspection threshold
•Kinetic perimetry
3.Corprehensive and versatile single analysis and reporting reliability: Accurate interpretation of perimetry results
•Perimeter index
•Dedicated projection perimetry software system
Specifications:
Model |
APS-T00 | |
Appearance |
Integrated Type | |
Stimulating way |
Optical projection | |
Projection surface |
aspheric projection arc | |
Detection method |
Static perimetry, Dynamic Perimetry | |
Detection scope |
0-90° | |
Brightness Level |
0-51db | |
Testing Distance |
300mm | |
Visual Target Color |
Red, Blue, White | |
Visual Target Brightness |
0asb-10000asb | |
Background Light |
White(31.5asb),yellow(315asb ) | |
Vision Target Interval time, keeping time |
Patients adaptive, standard, slow, custom | |
Pupil Size Measurement |
Auto | |
Head Movement Way |
AEC Eye position monitoring and automatic correction system | |
Brightness Measurement |
Brightness Auto Measurement and correction | |
Visual Target Size (Goldmann standard) |
G r a d e Ⅱ G r a d e Ⅲ G r a d e Ⅳ G r a d e Ⅴ G r a d e | |
Detection strategy |
Full-threshold, fast threshold, custom, Two notation,three notation,quantify defects,Intelligent dynamic, fast intelligent dynamic | |
Threshold policy |
age-related, threshold-related, single strength | |
Static Perimetry |
Threshold Test Mode |
Center 10-2,Center 24-2,Center 30-2,Center60-4,Nasal step, macula; |
Screening, special test mode |
Center 40,Center 64,Center 76;Center80,Center Armaly, Peripheral 60, Nasal step,Armaly Full Field,Full Field 81,Full Field 120, Full Field1 35, Full Field246,upper36, upper64, Esterman monocular,Estermanbinocular | |
Dynamic Perimetry |
Dynamic program |
manual procedures, standard procedures (Standard 45, standard 30, a high-resolution 15),Static point map, dark spot map, blind spot map, custom scan, custom dynamic program |
Stimulation parameters |
adjustable (Speed 1-9 / S, visual target size, color, intensity, test ranges, etc.) | |
Fixation monitoring |
Dynamic real-time video monitoring, physiological blind spot monitoring, | |
Eye tracking curve, eye position offset alarm | ||
Analysis Software |
Reliability analysis, single vision analysis, triple report analyzes, Overview vision analysis, GHT glaucoma semi vision analysis, GPA glaucoma developing analysis | |
Report Figure |
Value map, grayscale map , the overall bias decibel chart, The overall deviation probability map, chart pattern deviation decibels, Pattern deviation probability plot, staring Figure |